TCS is proud to present its new and upgraded generation of fuse blocks that offer more benefits than ever before, while not losing any of the existing features.  The Mo'protection range has a module and cable solution for all major PLC types and provides fused protection to reduce exposure from component failure that could cripple an automated plant.

Major Features of Mo'protection

Markedly reduces PLC panel assembly time

Factory assembled and tested wiring looms

Panel cable numbering no longer required. DIN rail mounted chassis. To all standards (European equivalent – EN50 022,35,45) Spring Cage or Screw Connectors. 

Fast efficient field connection with constant cable tension

Standardised cabling system for all I/O module types

One cable fits all for ControlLogix and Honeywell Plantscape

Intuitive field termination numbering system – alternate number shading for alignment

Power on LED indication

Multi-tier terminal blocks for minimal panel space requirement

Analogue modules with in-circuit current testing

Digital input modules with dip switch isolation features

Simplified ordering / catalogue numbers

Digital Fused Modules

16 & 32 way 24VDC input and output modules

  • Individually, electronically fused digital outputs
  • Sectionalised fused inputs
  • Individual dip switch isolation for digital inputs
  • Input & output LED status indication
  • Input (sectionalised) & output (individual) blown fuse indication
  • Power on indication
  • Sinking (SK) or Sourcing output modules
 
Analogue Fused Modules
  • 8 & 16 way input modules
  • 8 way output module
  • In-circuit current testing
  • Analogue input channels are dip switch selectable: voltage / current / single-ended / differential
  • Individually fused inputs & outputs
  • Ground plane for greater EMI and RFI screening
 
Relay Modules
  • 32 & 16 way relay output modules
  • 16 way relay input module
  • Normally open clean contact for output (0 to 260VAC-VDC)
  • Individual outputs up to 5 Amps.  Total section loading not exceeding 20 Amps
  • 230VAC relay input to 24VDC PLC module
  • Input & Output LED status indication
  • Sinking (SK) or Sourcing output modules
  • Fused 16 way relay output module (Each output Fused)
  • 16 Isolated outputs (with clean contact ie : no common earth between any output)
 
Straight through Modules
  • 20 & 36 way modules (anaolgue, digital, other)
  • Minimal PLC panel assembly time
  • Common module fuse connection
  • Power on and blown fuse indication
  • Common module for input and output
  • 2 or 3 tier spring cage connectors

 
Cables
  • ControlLogix and Honeywell Plantscape
  • Common cable for input/output and digital / analogue modules
  • To order, need only state 20 or 36 way connector and cable length (in metres)
  • Standard lengths are 1.0m, 2.0m, 3.0m or custom lengths can be ordered.
  • Other PLC types (OMRON, SIEMENS, AB, Modicon etc) to order, need to state PLC type, module type, and cable length.
  • 16 way Flex/Rail digital input or output comb headers
 
Accessories

Combiner modules
32 way PLC input or output module to 2 x 16 way fused input or output modules. (ie. 24VDC input and 230VAC input)

Combiner module cables (2 per combiner module).  50 way IDC to 50 way IDC.

Field wire terminal connectors for all major PLC types